EasyManua.ls Logo

Star TSP700II SERIES - 11-4. Ethernet Interface Model

Star TSP700II SERIES
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 47 –
11-4. Ethernet Interface Model
ON ON
OFF OFF
DIP-SW 1
Switch Function ON OFF
1-1 Command emulation (Ster Line mode) Always ON
1-2 Should not be changed (Should be set to on)
1-3 Should not be changed (Should be set to on)
1-4 Sensor adjustment Invalid Valid
1-5 Should not be changed (Should be set to on)
1-6 Handshaking conditions (conditions for
BUSY)
Offline or receive
buffer full
Receive buffer full
1-7 Should not be changed (Should be set to on)
1-8 Should not be changed (Should be set to on)
1-9 Low-power consumption mode Invalid Valid
1-10 Should not be changed (Should be set to on)
The factory settings of DIP switch are all on.
DIP-SW 2
Switch Function ON OFF
2-1~2-4 Always ON Should be set to on
The factory settings of DIP switch are all on.
No. 1 2 3 4 5 6 7 8 No. 1 2 3 4
9 10
DIP-SW 1 DIP-SW 2

Table of Contents