Troubleshooting
Problem Possible cause Remedy
Air bubbles escape from the
injection nozzle or the pump emits
unusual noises.
The pump is sucking in air. Check all hoses and gaskets for leaks.
Retighten the hose clamps.
Check the water level in the pool and fill
with more water if necessary until the
pool water covers the suction line
connection by approx. 2.5 - 5 cm (1 to 2
in).
The water level in the pool is too
low.
Raise the water level in the pool.
The prefilter basket (if present)
is clogged.
Empty the prefilter basket.
The suction line is out of place
or clogged.
Clean the suction line.
After the pump has been switched
on, the timer LED does not flash
and the pump does not start up.
The pump has no power. Connect the pump's power plug to the
power supply. Check whether the fuse
has tripped.
The pump is defective. Contact customer service.
The pump is not running. The timer is set. Press the timer button. The running time
can be set when the pump is switched off.
Turn on the pump.
The external timer is set. Check the running times on the external
timer.
If the problem cannot be solved, contact the customer service listed on the last page.