Loading...
Full Digital Stepper Drive DM542S
- 9 -
6. DIP Switch Setting
6.1 Current Setting
The current setting is in the following table.
6.2 Standstill current Setting
SW4 is used for setting the standstill current , “off” means the standstill current is
set to be half of the selected dynamic current or other current. While “on” means
the standstill current is set to be the same as the selected dynamic current.
6.3 Microsteps Setting
The Microsteps setting is in the following table.
Dial switch
Current
SW1
SW2
SW3
RMS
1.0A
on
on
on
1.46A
off
on
on
1.91A
on
off
on
2.37A
off
off
on
2.84A
on
on
off
3.31A
off
on
off
3.76A
on
off
off
4.2A
off
off
off