Stonex R180 – User Manual 42
7. Technical Data
ANGLE MEASUREMENT
Accuracy
1
0.5”-1”
Reading system
Absolute four-quadrant
Display Resolution
0.1
Angle Units
DEG 360°/GON 400/MIL 6.400
TELESCOPE
Magnification/ Field of view
30x / 1°30’
Tube length
164.5 mm
Minimum focus distance
1.5 m
Objective aperture
Ø 45 mm
Laser pointer
Red light, coaxial
TILT SENSOR
Type
Dual-axis liquid-electric sensor
Compensation range/accuracy
± 3.0'/1”
DISTANCE MEASUREMENT RANGE
2
Standard prism mode
6000 m
3
Reflectorless
5
1000 m
4
DISTANCE MEASUREMENT ACCURACY
6
Standard prism mode
1 mm + 1 ppm
Reflectorless
2 mm + 2 ppm
MEASUREMENT TIME
Standard prism mode
(Tracking/Single)
<0.3 / 0.7 sec
Reflectorless
Typically 0.8 sec (>500 m, >5 sec)
DISTANCE MEASUREMENT
Distance Unit
m/US ft/INT ft
Display Resolution
0.0001 m/0.001 m
0.001 ft/0.01 ft
MOTORIZATION
Technology
Tdrive
Max rotation speed
180°/sec
APC-Target Aiming Range
1.5 - 1000 m
APC-Measurement Time
<10 sec