EasyManua.ls Logo

Structural Concepts Oasis MI44RF - Preventive Maintenance (Performed by Trained Service Provider)

Structural Concepts Oasis MI44RF
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
PREVENTIVE MAINTENANCE (TO BE PERFORMED BY TRAINED SERVICE PROVIDER)
Area of
Case
FREQ. INSTRUCTIONS
Case
Exterior
Monthly Condensing Coil:
Remove panel to access area by lifting up and off (no screw removal is
required; simply lift up and off)
Use air pressure or industrial strength vacuum; clean dust and dirt that may
collect on the condenser coil.
Use wet rags to cover
area where air pressure is blowing.

Return panel to case.
Quarterly Condensate Package / Overflow Condensate Pan / Compressor Area: Caution!
Be certain to disconnect power from case before cleaning condensate package!
Slide/roll compressor package out from under case.
Use a scrub-brush and a de-scaling solution such as CLR® (to prevent
corrosion, lime and rust). Follow instructions as to proper dilution, safety
precautions and scrubbing method.
Electric heater coil condensate pans can be removed and cleaned.
After thoroughly cleaning pan with scrub-brush and solution, rinse thoroughly
with clean water (in spray bottle) and wipe dry with sponge or paper towel.
Use moist cloth to wipe off dust & debris that collects on various parts (fans,
sight glass, overflow pan, etc.).
Slide refrigeration assembly back under case.
Replace lower panel via hook/magnet method (no screws required).
Quarterly Under Case Cleaning: Once condenser package is clear of unit, vacuum under
case to remove dust and dirt that collects under case.
Case
Interior
Quarterly Tub, Coil, Drain, Fan Blade, Motor, Bracket:
Disconnect power from the case before cleaning the Tub, Coil, Fan, Motor and Drain
Area!
Remove decking, sub-deck and fan shroud.
Use vacuum to clean evaporator coils.
Clean tub, coil and drain with warm water, clean cloth, brush and mild soap
solution.
Remove any debris that may clog drain.
Clean fan blade, motor and bracket by wiping down with moist cloth.
Quarterly Honeycomb Air Diffusers:
Remove honeycomb air diffuser from case.
Vacuum.
Clean with warm water and soap.
Return to case.
See -
in manual for removal/replacement illustrations.
WARNING! TURN OFF CASE BEFORE PERFORMING PREVENTIVE MAINTENANCE!