5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
PTC 140°C
MAIN DISC MOTOR
3 D
370W
200V
250Hz
M1
Belt 1 : 6
200mm GRINDING DISC
MPT / OHO
50-500/600
RPM CCW
THIS DOCUMENT CONTAINS CONFIDENTAL AND PROPRIETARY INFORMATION THAT IS THE SOLE PROPERTY OF STRUERS A/S („STRUERS“) AND NO OWNERSHIP OR LICENSE RIGHT
ARE GARANTED BY DELIVERY OF THIS DOCUMENT TO THE RECEPIENT. THIS DOCUMENT AND ALL INFORMATION DISCLOSED HEREIN (A) SHALL NOT BE USED TO MANUFACTURE,
CONSTRUCT OR FABRICATE THE GOODS DISCLOSED HEREIN OR ANY DERIVATIVE WORKS OF THE SAME; (B) SHALL NOTBE EXPLOITED OR SOLD BY ANY MEANS; (C) SHALL NOT BE
COPIED OR OTHERWISE REPRODUCED IN WHOLE OR IN PART; (D) SHALL NOT BE REVEALED OR DISCLOSED TO ANYONE EXCEPT THOSE PERSONS EMPLOYED OR ENGANGED BY THE
RECEPIENT AND HAVING A LEGITIMATE „NEED TO KNOW“ THE INFORMATION CONTAINED IN THIS DOCUMENT, OR IN ANY MANNER MADE PUBLIC WITHOUT THE EXPRESS WRITTEN
PERMISSION OF STRUERS; (E) SHALL BE HELD BY RECEPIENT OF THIS DOCUMENT IN STRICT CONFIDENCE AS A FIDUCIARY; AND (F) SHALL BE PROTECTED AND KEPT SEPARE FROM
THE DOCUMENTS AND MATERIALS OF THE RECEPIENT OF THIS DOCUMENT. THIS DOCUMENT AND ALL INFORMATION CONTAINED HEREIN SHALL REMAIN PROPERTY OF STRUERS AND
SHALL BE RETURNED UPON DEMAND ALL PROPRIETARY INFORMATION IS PROVIDED „AS IS“ WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT
LIMITATION ANY WARRANTIES REGARDING THE TIMELINESS, ACCURACY OR COMPLETENESS OF THE PROPRIETARY INFORMATION.
A
REV NOTES
Rev. A (MPT 2017-02-02)
Derived from doc. 16323050B;
relay K1 added; circuit updated
Sink driver
ON/OFF logic
L1 + N
OR
L1 + L2
3
Power
output
Temperature
measurement
input
Main Supply Input
WATER VALVE
INPUT FILTER
2
Mains cables:
C13 --- Schuko (0.75mm2)
C13 --- NEMA 6-15 (AWG16)
2
Switch Fuses: 6.3AT
F1-F2
QS1
Power Supply
Input: 85-264Vac
Output: 24Vdc, 4.2A
A1
2
Z1
A2
Y1
200-240V, 50-60Hz
Power
input
2
PE
4
2
PE
RELAY
K1
FREQUENCY
INVERTER
370W
Safety
Torque
Off
S1.1
GND
RPM 50-500
Input for RUN
Input for SPIN
X1
Con. inside
metal tube
CONNECTION TO
USER INTERFACE
LABOFORCE-50/Mi
Emergency
stop
2 5
+24V-2
S1.2
Emergency
stop
2
2
2
Size
Scale
CAGE Code
DWG NO
R e v
Sheet
o f
telephone: +45 44 600 800
Struers A/S
16323051
Tuesday, April 04, 2017
1 1
A2
Pederstrupvej 84
DK-2750 Ballerup
Denmark
Labopol-20, Block Diagram
Size
Scale
CAGE Code
DWG NO
R e v
Sheet
o f
telephone: +45 44 600 800
Struers A/S
16323051
Tuesday, April 04, 2017
1 1
A2
Pederstrupvej 84
DK-2750 Ballerup
Denmark
Labopol-20, Block Diagram
Size
Scale
CAGE Code
DWG NO
R e v
Sheet
o f
telephone: +45 44 600 800
Struers A/S
16323051
Tuesday, April 04, 2017
1 1
A2
Pederstrupvej 84
DK-2750 Ballerup
Denmark
Labopol-20, Block Diagram