Parameter
Unit
12
24
48
Mod.
value
Factory
Min
Max
Factory
Min
Max
Factory
Min
Max
Expert
1227
Battery overvoltage (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1228
Inverter or Smart- Boost overload (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1229
Overtemperature (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1520
No overtemperature (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1231
Active charger (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1232
Active inverter (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1233
Active Smart-Boost (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1234
AC input presence but with fault (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1235
AC input presence (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1236
Transfer relay ON (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1237
AC-Out presence (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1238
Bulk charge phase (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1239
Absorption phase (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1240
Equalization phase (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1242
Floating (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1243
Reduced floating (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1244
Periodic absorption (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Inst.
1601
AC-In energy quota (AUX1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1245
Contact active according to battery voltage
(AUX 1)
Expert
1288
Use dynamic compensation of battery level
(AUX 1)
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1246
Battery voltage 1 activate (AUX 1)
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1247
Battery voltage 1 (AUX 1)
Vdc
11.7
9
18
23.4
18
36
46.8
36
72
Expert
1248
Delay 1 (AUX 1)
min
1
0
60
1
0
60
1
0
60
Expert
1249
Battery voltage 2 activate (AUX 1)
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1250
Battery voltage 2 (AUX 1)
Vdc
11.9
9
18
23.9
18
36
47.8
36
72
Expert
1251
Delay 2 (AUX 1)
min
10
0
60
10
0
60
10
0
60
Expert
1252
Battery voltage 3 activate (AUX 1)
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1253
Battery voltage 3 (AUX 1)
Vdc
12.1
9
18
24.2
18
36
48.5
36
72
Expert
1254
Delay 3 (AUX 1)
min
60
0
60
60
0
60
60
0
60
Expert
1255
Battery voltage to deactivate (AUX 1)
Vdc
13.5
9
18
27
18
36
54
36
72
Expert
1256
Delay to deactivate (AUX 1)
min
60
0
480
60
0
480
60
0
480
Expert
1516
Deactivate if battery in floating phase (AUX
1)
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1257
Contact active with inverter power or Smart-
Boost (AUX 1)
Expert
1258
Inverter power level 1 activate (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1259
Power level 1 (AUX 1)
% Pnom
120
20
120
120
20
120
120
20
120
Expert
1260
Time delay 1 (AUX 1)
min
1
0
60
1
0
60
1
0
60
Expert
1261
Inverter power level 2 activate (AUX 1)
No/Yes
No
-
-
No
-
-
No
-
-

Table of Contents