Studer Innotec SA
RCC-02/-03
User manual V4.4.0 91
Level
User
ref.
Parameter
Unit
12
24
48
Mod.
value
Factory
Min
Max
Factory
Min
Max
Factory
Min
Max
Expert
1333
Xtender is OFF (AUX 2)
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1519
Xtender ON (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1544
Remote entry (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1334
Battery undervoltage alarm (AUX 2)
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1335
Battery overvoltage (AUX 2)
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1336
Inverter or Smart-Boost overload (AUX 2)
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1337
Overtemperature (AUX 2)
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1521
No overtemperature (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1339
Active charger (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1340
Active inverter (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1341
Active Smart-Boost (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1342
AC input presence but with fault (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1343
AC input presence (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1344
Transfer contact ON (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1345
AC-Out presence (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1346
Bulk charge phase (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1347
Absorption phase (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1348
Equalization phase (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1350
Floating (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1351
Reduced floating (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1352
Periodic absorption (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Inst.
1602
AC-In energy quota (AUX2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1353
Contact active according to battery voltage
(AUX 2)
Expert
1354
Use dynamic compensation of battery level
(AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1355
Battery voltage 1 activate (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1356
Battery voltage 1 (AUX 2)
Vdc
12
9
18
24
18
36
48
36
72
Expert
1357
Delay 1 (AUX 2)
min
5
0
60
5
0
60
5
0
60
Expert
1358
Battery voltage 2 activate (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1359
Battery voltage 2 (AUX 2)
Vdc
11.5
9
18
23
18
36
46.1
36
72
Expert
1360
Delay 2 (AUX 2)
min
5
0
60
5
0
60
5
0
60
Expert
1361
Battery voltage 3 activate (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1362
Battery voltage 3 (AUX 2)
Vdc
11
9
18
22.1
18
36
44.2
36
72
Expert
1363
Delay 3 (AUX 2)
min
5
0
60
5
0
60
5
0
60
Expert
1364
Battery voltage to deactivate (AUX 2)
Vdc
12.6
9
18
25.2
18
36
50.4
36
72
Expert
1365
Delay to deactivate (AUX 2)
min
5
0
480
5
0
480
5
0
480
Expert
1517
Deactivate if battery in floating phase (AUX
2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1366
Contact active with inverter power or Smart-
Boost (AUX 2)