EasyManuals Logo

Studer RCC-03 User Manual

Studer RCC-03
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
Studer Innotec SA
RCC-02/-03
92 V4.4.0 User manual
Level
User
ref.
Parameter
Unit
12
24
48
Mod.
value
Factory
Min
Max
Factory
Min
Max
Factory
Min
Max
Expert
1367
Inverter power level 1 activate (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1368
Power level 1 (AUX 2)
% Pnom
120
20
120
120
20
120
120
20
120
Expert
1369
Time delay 1 (AUX 2)
min
0
0
60
0
0
60
0
0
60
Expert
1370
Inverter power level 2 activate (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1371
Power level 2 (AUX 2)
% Pnom
80
20
120
80
20
120
80
20
120
Expert
1372
Time delay 2 (AUX 2)
min
5
0
60
5
0
60
5
0
60
Expert
1373
Inverter power level 3 activate (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1374
Power level 3 (AUX 2)
% Pnom
50
20
120
50
20
120
50
20
120
Expert
1375
Time delay 3 (AUX 2)
min
30
0
60
30
0
60
30
0
60
Expert
1376
Inverter power level to deactivate (AUX 2)
% Pnom
40
20
120
40
20
120
40
20
120
Expert
1377
Time delay to deactivate (AUX 2)
min
5
0
60
5
0
60
5
0
60
Inst.
1504
Contact active according to battery temperature
(AUX 2) With BSP or BTS
Inst.
1457
Contact activated with the temperature of
battery (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Inst.
1458
Contact activated over (AUX 2)
°C
3
-10
50
3
-10
50
3
-10
50
Inst.
1459
Contact deactivated below (AUX 2)
°C
5
-10
50
5
-10
50
5
-10
50
Expert
1502
Contact active according to SOC (AUX 2) Only
with BSP
Expert
1442
Contact activated with the SOC 1 of battery
(AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1443
Contact activated below SOC 1 (AUX 2)
% SOC
50
0
100
50
0
100
50
0
100
Expert
1590
Delay 1 (AUX 2)
h
12
0
99
12
0
99
12
0
99
Expert
1591
Contact activated with the SOC 2 of battery
(AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1592
Contact activated below SOC 2 (AUX 2)
%
30
0
100
30
0
100
30
0
100
Expert
1593
Delay 2 (AUX 2)
h
0.2
0
99
0.2
0
99
0.2
0
99
Expert
1594
Contact activated with the SOC 3 of battery
(AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1595
Contact activated below SOC 3 (AUX 2)
%
20
0
100
20
0
100
20
0
100
Expert
1596
Delay 3 (AUX 2)
h
0
0
99
0
0
99
0
0
99
Expert
1444
Contact deactivated over SOC (AUX 2)
% SOC
90
0
100
90
0
100
90
0
100
Expert
1597
Delay to deactivate (AUX 2)
h
0.2
0
10
0.2
0
10
0.2
0
10
Expert
1598
Deactivate if battery in floating phase (AUX
2)
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1513
Security, maximum time of contact (AUX 2)
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1515
Maximum time of operation of contact (AUX 2)
min
600
10
1200
600
10
1200
600
10
1200
Expert
1570
Reset all settings (AUX 2)
-
-
-
-
-
-
-
-
-
Expert
1489
AUXILIARY CONTACTS 1 AND 2 EXTENDED
FUNCTIONS
Expert
1491
Generator control active
No/Yes
No
-
-
No
-
-
No
-
-

Table of Contents

Other manuals for Studer RCC-03

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Studer RCC-03 and is the answer not in the manual?

Studer RCC-03 Specifications

General IconGeneral
BrandStuder
ModelRCC-03
CategoryExtender