NOTICE: Surface temperature of adjacent walls and mantels become hot during operation.
Walls and mantels above the rebox may become too hot to touch. If installed properly, these
temperatures meet the requirement of the national product standard. Follow all minimum
clearances shown in this manual.
NOTICE: If your installation does not meet the minimum clearances shown, you must do one of
the following: Operate the logs with the ue damper open only. Raise the mantel to an
acceptable height.
FLOOR CLEARANCES
a) If installing appliance on oor level, you must maintain the minimum distance of 14
in. to combustibles (see Fig. 7).
b) If combustible materials are less than 14 in. to the replace, you must install
appliance at least 5 in. above the combustible ooring (see Fig. 8).
Fig. 7- Minimum replace
clearances if installed at oor level
Combustible
Material
14 in.
Min
Noncombustible
Material
Fig. 8 - Minimum replace clearances
above combustible ooring
Combustible
Material
5 in.
Min
Hearth
Fig. 9 - Attach Damper to Fireplace
Damper
Damper
Clamp
Damper