NOTICE: Surface temperature of adjacent walls and mantels become hot during operation.
Walls and mantels above the rebox may become too hot to touch. If installed properly, these
temperatures meet the requirement of the national product standard. Follow all minimum
clearances shown in this manual.
NOTICE: If your installation does not meet the minimum clearances shown, you must do one of
the following: Operate the logs with the ue damper open only. Raise the mantel to an
acceptable height.
FLOOR CLEARANCES
a) If installing appliance on oor level, you must maintain the minimum distance of 14
in. to combustibles (see Fig. 7).
b) If combustible materials are less than 14 in. to the replace, you must install
appliance at least 5 in. above the combustible ooring (see Fig. 8).
Fig. 7- Minimum replace
clearances if installed at oor level
Combustible
Material
14 in.
Min
Noncombustible
Material
Fig. 8 - Minimum replace clearances
above combustible ooring
Combustible
Material
5 in.
Min
Hearth
Fig. 9 - Attach Damper to Fireplace
Damper
Damper
Clamp
Damper