EasyManua.ls Logo

Style selections SSEB18RT - Safety Pilot; 2 Gas Options Capable; Local Codes; Product Features

Style selections SSEB18RT
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system.
The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic piezo control system. This system requires
one (1) AAA battery (provided).
2 GAS OPTIONS CAPABLE
Your heater is equipped to operate on either propane or natural gas. The heater is
shipped from the factory ready for connecting to propane. The heater can easily be
changed to natural gas by having your qualied installer follow the instructions on page
18 and the markings on the heater.
State of Massachusetts: The installation must be made by a licensed plumber or gas
tter in the Commonwealth of Massachusetts. Sellers of unvented propane or natural
gas-red supplemental room heaters shall provide to each purchaser a copy of
527 CMR 30 upon sale of the unit.
In the State of Massachusetts, unvented propane or natural gas-red space heaters shall
be prohibited in bedrooms and bathrooms.
In the State of Massachusetts the gas cock must be a T-handle type. The State of
Massachusetts requires that a exible appliance connector cannot exceed three feet
in length.
LOCAL CODES
Install and use heater with care. Follow all codes. In the absence of local codes, use the latest
edition of The National Fuel Gas Code, ANSI Z223.1, also known as NFPA 54*.
*Available from:
American National Standard Institute, Inc National Fire Protection Association, Inc.
1430 Broadway 1 Batterymarch Park
New York, NY 10018 Quincy, MA 02269-9101
This heater is designed for vent-free operation. State and local codes in some areas prohibit the
use of vent-free heaters.
PRODUCT FEATURES
This log set has been tested and approved to ANSI Z21.11.2 standard for Unvented Heaters
and can be operated with the flue damper closed. State and local codes in some areas
prohibit the use of vent-free heaters.