1600C LP USER MANUAL SECTION 6
70
6.3 NOISE EMISSIONS MAINTENANCE & MAINTENANCE RECORD LOG
The following instructions and maintenance record log book, for the proper maintenance, use and repair of this
compressor, is intended to prevent noise emission degradation.
NOISE EMISSION MAINTENANCE & MAINTENANCE RECORD LOG
1. ANNUAL MUFFLER AND EXHAUST SYSTEM INSPECTION
At least annually inspect muffler(s) and engine exhaust system to make sure all parts are securely mounted, that all joints
and connections are tight, and that the muffler is in good condition. DO NOT operate compressor with defective exhaust
system. Remove and replace any defective parts by ordering with part numbers indicated in the Parts List.
Maintenance Performed
By
Location
Date
Maintenance Performed
By
Location
Date
2. ANNUAL AIR FILTER(S) AND AIR INLET SYSTEM INSPECTION
In addition to the instructions in the Maintenance section of the Operator’s Manual, the air filter(s) and entire air inlet system
should be inspected at least annually, to make sure all parts are securely mounted, that all joints and connections are tight,
that there are no other leaks in the system, and that the filter element(s) are intact. DO NOT operate compressor with
defective air inlet system. Remove and replace defective parts by ordering with part numbers indicated in the Parts List.