SECTION 5 600H, 750, 750H, 750HH, 825, 900, 900H USER MANUAL
57
5.10 MAINTENANCE EVERY 1500
HOURS
When using Sullair AWF, change the compressor
fluid and replace the fluid filter element.
Refer to Parts Replacement And Adjustment
Procedures in Section 5 on page 57.
5.11 PARTS REPLACEMENT AND
ADJUSTMENT
PROCEDURES
COMPRESSOR FLUID CHANGE PROCEDURE
Warm-up the compressor for 5 to 10 minutes to
warm the fluid. Shut the compressor off and relieve
all internal pressure before proceeding. Drain the
fluid by opening the appropriate drain valve located
in the frame at the front of the machine. Close the
valve when draining is complete. Change the
compressor fluid and replace the fluid filter element.
For element replacement see procedure for servicing
the fluid filter in this section. Fill the receiver tank with
fluid according to Lubrication Guide in Section 3 on
page 44.
RUNNING GEAR LUBRICATION
Refer to Figure 5-1. An inspection of the running gear
should be made on a routine basis. On four-wheel
steerable running gear models, front-axle pivot joints
and rod ends are fitted with grease zerks which
should be lubricated every six months.
Figure 5-1: Running Gear Lubrication