10 Sun Fire V890 Dynamic Reconfiguration User’s Guide August 2004
Accessing the Detailed Status Display
You can use the -v (verbose) option to access expanded descriptions.
For a more detailed status report, as superuser, type:
In addition to the information provided by the basic status display, the detailed
status information includes the physical attachment point of each card.
The following is an example of the display produced by the cfgadm -v command.
Receptacle empty Slot is empty
connected Slot is electrically connected
disconnected Slot is not electrically connected
Occupant configured Board or card is logically attached to the operating system
unconfigured Board or card is logically detached from the operating system
Condition ok Board or card is ready for use
unknown Board or card condition cannot be determined
failing A board or card that was in the OK condition has developed a
problem
failed Board or card has failed
unusable Either an attachment point has incompatible hardware or an
empty attachment point lacks power or precharge current
# cfgadm -v
Column Entry Meaning

Other manuals for Sun Microsystems Sun Fire V890

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun Fire V890 and is the answer not in the manual?

Sun Microsystems Sun Fire V890 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun Fire V890
CategoryServer
LanguageEnglish

Related product manuals