26 Sun Fire X4150 Server Product Notes • February 2010
Workaround
Apply counter-pressure to the DVD assembly when removing a USB device. In
addition, do not remove a USB device when the DVD is operating. This issue will be
addressed in the future with a redesigned DVD assembly.
Important Note on Inserting a Hard Disk Drive
When inserting a hard disk drive, do not extend the lever past 70 degrees. If the
lever is extended past 70 degrees on insertion there is a risk that the right most tab
will break off. The end result of accidentally breaking off the tab is purely cosmetic—
the drive will still function properly if fully inserted.
System Management Issues
With Tools and Drivers CD 2.0, you now have the option to install either ELOM or
ILOM system management software on your system.
Refer to the following documentation for additional information on system
management for the Sun Fire X4150 server:
■ ELOM information: Embedded Lights Out Manager Administration Guide for the Sun
Fire X4150 Server
■ ILOM information: Integrated Lights Out Manager 2.0 User’s Guide
■ ELOM to ILOM transition: ELOM-to-ILOM Migration User’s Guide
The issues in this section fall into one of three categories:
■ “ILOM 3.0 Issues” on page 26
■ “ILOM and ELOM System Management Issues” on page 28
■ “ELOM System Management Issues” on page 34
■ “ILOM System Management Issues” on page 36
ILOM 3.0 Issues
The following issues are specific to ILOM 3.0. Additional ILOM 3.0 information is
available in Sun Integrated Lights Out Manager (ILOM) Feature Updates and Release
Notes. This document is available at:
http://docs.sun.com/app/docs/coll/ilom3.0