Sun Fire X4150 Server Product Notes 27
The System Shuts Down When CPU Temperature
Rises Without SEL or LED Notification (6790299)
When the CPU temperature reaches its upper critical limit, the system shuts down,
though there is no event logged in the system event log (SEL) and the Tempfail LED
does not light.
Do Not Start New Flash Process While SP Is
Already in a Flash Process (6778713)
While the SP is being updated (flashed), do not start a new flash process. Wait until
the current flash is completed before you start a new one.
ILOM Update To or From ILOM 3.0 Causes BIOS
Version to Not Be Viewable (6789995)
When ILOM is downgraded from ILOM 3.0 to ILOM 2.0 or upgraded from ILOM 2.0
to 3.0, the BIOS version might not appear in the Firmware Upgrade section of the
web interface.
TABLE 3 indicates when you can expect to see the BIOS version
viewable in the Firmware Upgrade section of the ILOM web interface.
Workaround
If you can not get the BIOS version from web interface while it is updating, you can
view the BIOS version connected with the ILOM version from these product notes.
See “Tools and Drivers CD/DVD” on page 4.
If the BIOS is currently running and not in update mode, you can obtain the BIOS
version from BIOS Setup utility or ILOM CLI.
TABLE 3 When BIOS Viewable in Web Interface
ILOM State
BIOS Update
Required?
Existing BIOS Version
Viewable in Web
Interface?
New BIOS Version
Viewable in Web
Interface?
Upgraded from 2.0 to 3.0 Optional No Yes
Downgraded from 3.0 to 2.0 Mandatory No No