User Manual 2 Product Description
11
2.3.2 Function Description
Inversion function
Inverter converts the DC current into grid-compatible AC current and feeds the
AC current into grid.
Data storage and display
Inverter achieves the running information, fault records and etc. and displays
them on the integrated LCD display.
Parameter Configuration
Inverter provides various parameter configuration for inverter optimal operation.
Communication Interface
Standard RS485 port, can be connected to monitoring device and PV system
Protection Function
Short-circuit protection
Ground insulation resistance detection
Inverter output voltage monitoring
Inverter output frequency detection
Residual current protection
DC injection of AC output current surveillance
Anti-islanding protection
Ambient temperature monitoring
DC over-voltage protection
Over-current protection
Power module over-temperature protection
2.3.3 Derating
Output derating is a way to protect the inverter from overload or potential faults.
Situations require inverter power derating are:
Internal temperature is too high (including ambient temperature and module
temperature)
Grid voltage is too low
External power class adjustment
Grid frequency is too high
[*]
Note: [*] valid only when the country selected is DE or IT.

Table of Contents

Other manuals for Sungrow SG80KTL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG80KTL and is the answer not in the manual?

Sungrow SG80KTL Specifications

General IconGeneral
BrandSungrow
ModelSG80KTL
CategoryInverter
LanguageEnglish

Related product manuals