We recommend the use of an RCD on all circuits and sub-circuits connected to the
Sunsynk Inverter. Below is the specifications for a Residual Current Breaker with
Overcurrent Protection (RCBO)
Earth-leakage protection class Type A
Earth-leakage sensitivity 30mA
Curve code C
Network type AC
Poles description 2P
Earth-leakage protection time delay Instantaneous
APPENDIX E
The Sunsynk inverter can be connected to the internet, but you need to add a data
logger to do this.
The inverter is compatible with Solar Man data-loggers, which you can obtain from us
with your distributor
1) LAN-Type Data Logger
2) Wi-Fi-Type Data Logger
3) GSM-Type Data Logger
To setup the Internet connection for the Data Logger, please refer to the App User
instructions. The Data Logger should be connected to the bottom of the inverter via the
connection socket marked Wi-Fi.