Features and how to configure ST940
1.19
0
19-06-15
15
22 of 51
<Example>
[command]
ST910;CGF;123456789;1;1;36.923548;127.309570;29;1;1
ST910;CGF;456789;1;1;36.923548;127.309570;29;1;1
[response]
ST910;RES;CGF;123456789;1;1;36.923548;127.309570;29;1;1
ST910;RES;CGF;456789;1;1;36.923548;127.309570;29;1;1
How to set Report Parameters
The following table shows how to set intervals of location report, alert and how to set sensor value to sense if any
motion is made.
Field
Marks
Value
Meaning
HDR
ST910
Model Name
COMMAND
“REPORT”
Command Type
DEV_ID
6 or 9 char.
Digits ID of device. It is a part of IMEI. Please check the
DEV_ID_TYPE” setting.
PARKING_INTRV
String
Second
Sending interval of location report while Parking
Range : 0 to 86400
If zero, the device doesn’t send location report periodically.
DRIVING_INTRV
String
Second
Sending interval of location report while Driving
Range : 0 to 6400
If zero, the device doesn’t send location report periodically.
EMERG_INTERVAL
String
Second
Sending interval of alert about carrying out
Range : 0 to 180
If zero, checking of carrying is disabled.
EMERG_NUM
String
Number of sending Emergency report until the device
receivesServer ACK
CARRY_THRES
String
Threshold value of the sensor to check if movement of the
object is made
Range: 0.0 to 2.0;
However, it is highly recommended that the value should be
0.10.