EasyManua.ls Logo

Supermicro SSE-G24-TG4 - Page 57

Supermicro SSE-G24-TG4
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Supermicro L2/L3 Switches Configuration Guide
57
maximum size of 200 entries
.
Step 3
e
nd
Exits the configuration mode.
Step 4
show logging
Displays the
Syslog
configuration.
Step 5
write startup
-
config
Optional step
saves this configuration
to be part of the startup configuration.
The
no
logging buffered
command
resets the Logging buffer to its default value of 50
entries.
The example below shows the commands used to configure the Syslog buffer.
SMIS# configure terminal
SMIS(config)# logging buffered 200
SMIS(config)# end
SMIS# show logging
System Log Information
----------------------
Syslog logging: enabled(Number of messages 0)
Console logging: disabled(Number of messages 0)
File logging: disabled(Number of messages 0)
Log File Name:
File Max Entries: 500
TimeStamp option: enabled
Trap logging: Critical
Log server IP: None
Facility: Default (local0)
Buffered size: 200 Entries
LogBuffer(11 Entries)
<135> Apr 29 10:11:05 2013:DHC-7:Exitting DHCPC Task Init
<135> Apr 29 10:11:05 2013:DHC-7:Entered in DhcpCIntSelectTaskMain fn
<135> Apr 29 10:11:05 2013:DHC-7:Entered in DhcpCSocketOpen fn
<135> Apr 29 10:11:07 2013:DHC-7:Rcvd Event 4
<135> Apr 29 10:11:07 2013:DHC-7:Rcvd Msg 13cb8128 type : 1
<135> Apr 29 10:11:07 2013:DHC-7:Rcvd Event 4