Chapter 2: Server Installation
Note: Figures are for illustrative purposes only. Always install servers to the bottom of a rack

Figure 2-4. Installing the Server into a Rack
2.5 Installing the Chassis into the Rack
1. 
the outer rails are installed on the rack.
2. Align the chassis rails with the front of the rack rails.
3. Slide the chassis rails into the rack rails, keeping the pressure even on both sides.
(It may be necessary to depress the locking tabs when inserting). When the server
has been pushed completely into the rack, the locking tabs will "click" into the locked
position.
4. Insert and tighten the screws that hold the front of the server to the rack.
2.6 Removing the Chassis from the Rack
1. Pull the chassis by the inner rail handles until the chassis is stopped by the locking tabs.
2. Press down on the locking tab while holding both side of the chassis.
3. Pull the chassis completely out of the rack.