4-6
X10DRS-2U/3U/4U Motherboard User’s Manual
AC Loss Policy Depend On
Select BIOS for the AMI BIOS to set the AC power loss policy. Select IPMI for the
IPMI to set the AC power loss policy. The options are IPMI and BIOS.
Restore on AC Power Loss
Use this feature to set the power state after an AC power outage. Select Power
O󰀨 for the system power to remain o󰀨 after a power loss. Select Power On for the
system power to be turned on after a power loss. Select Last State to allow the sys-
tem to resume its last power state before a power loss. The options are Power On,
Stay O󰀨, and Last State.
CPU Conguration
This submenu displays the following CPU information as detected by the BIOS. It
also allows the user to congure CPU settings.
Processor Socket
Processor ID
Processor Frequency
Processor Max Ratio
Processor Min Ratio
Microcode Revision
L1 Cache RAM
L2 Cache RAM
L3 Cache RAM
CPU1 Version
CPU2 Version
Clock Spread Spectrum
Select Enable to allow the BIOS to attempt to reduce the level of Electromagnetic
Interference caused by the components whenever needed. The options are Dis-
able and Enable.

Table of Contents