7. Safety instructions
Exceeding the maximum permissible running time
(KB) may overload and damage the superrollo
GW180 / GW185.
◆ The maximum permissible running time for a cycle
may not be exceeded when the equipment is in oper-
ation. For this reason, the superrollo GW180 / GW185
has an automatic running time limit (KB) of four
minutes.
◆ If the running time limit is triggered, then the
superrollo GW180 / GW185 must be left for at least 12
minutes to cool down. During this period, the indica-
tor light ashes rapidly. Full operational availability
is re-established after approx. one hour.
i
Only use the superrollo GW180 / GW185 for opening and
closing at roller shutters with a permissible belt.
According to DIN EN 13659, it is necessary to determine
that the movement conditions for the shutters are
maintained in accordance with EN 12045.
◆ The displacement must be of at least 40 mm on the
lower edge in the rolled-out position with a force of
150 N in the upwards direction.
◆ In doing so, it must be ensured that the extending
speed of the shutters for the nal 0.4 m is less than
0.15 m/s.
7.1 Intended use
i
Mechanical locks of any kind are not suitable
for automated operation with this device.