EasyManua.ls Logo

SureCall Flare 3.0 - TROUBLESHOOTING

SureCall Flare 3.0
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SureCall Flare 3.0 | Specifications
17
1-888-365-6283 | support@surecall.com | www.surecall.com
1-888-365-6283 | support@surecall.com | www.surecall.com
TROUBLESHOOTING
If you have any questions during setup, please reach out to our US-based experienced support technicians:
Call: 1-888-365-6283, Email: support@surecall.com, or Visit: www.surecall.com/support
Problem Resolution
Signal booster has no
power
Connect the power supply to an alternate power source.
Be sure the power source is not controlled by a switch that can remove power from the outlet.
Check the POWER LED () on the signal booster. If it is OFF, contact tech support at:
1-888-365-6283 or support@surecall.com, or go to www.surecall.com/support
After installing your signal
booster system, you have
no signal or reception
Verify that cable connections are tightly fitted to the booster and antenna.
Try further separating the booster and antenna.
Verify that there is usable signal where the antenna is placed.
Remember: Bars are not always a reliable measure of signal. The best way to confirm signal
coverage is the ability to place and hold a call.
SPECIFICATIONS
Flare 3.0 (U.S.) ; Flare 3.0 CA (Canada)
Uplink Frequency Range (MHz): 698–716 / 776–787 / 824–849 / 1850–1915 / 1710–1755
Downlink Frequency Range (MHz): 728–746 / 746–757 / 869–894 / 1930–1995 / 2110–2155
Donor/Server Port Impedance: 75 ohm / 50 ohm
Maximum Gain: 72 dB
Noise Figure: 7 dB
VSWR: ≤2.0
Supported Standards: 4G / LTE / 5G cellular standards
AC Input: Input: AC 110 – 240 V, 60 Hz ; Output: DC 5V / 3A
Maximum Output Power: 1 Watt EIRP
Cable: RG6 (50 ft.)
RF Connectors: Donor port: F Female, Server port: Integral
Power Consumption: <12W
Weight: 1. 8125 lb.
Dimensions: 5.125 × 7.25 × 5.625 inches
Certifications: FCC ID: RSNFLARE-3 ; IC : 7784A-FLARE3
Note: The term “IC” before the radio certification number only signifies that Industry Canada technical specifications were met.