55--6655
(3) Trim Set
There are three trimming-related settings: Trimming start angle setting, main-shaft start acceleration speed
setting, and bartack length setting for trimming.
Trim Angle Setting
This function is to change the main shaft angle when the trimming motor feed begins.
The default is 0, and the value can be adjusted from -5to 5by the unit of 1.
Accelation
This function is to set the time taken for the machine to reach the embroidery speed after the machine started
operating at the inching speed.
The default is Normal. Either Normal(0) or Slow(1) can be chosen.
embroidery speed
inching speed
Time
start
t
[Fig. 5.4.7-6]