3. The operating pressure for the gas supply
is 30mbar (or 28mbar butane/37mbar
propane) and must correspond to the
operating pressure of the appliance (see
name plate).
4. Do not operate the water heater when
refuelling the vehicle and when in the
garage.
5. During the initial operation of a brand new
appliance (or after it has not been used
for some time), a certain amount of
fumes, and a slight smell, may be noticed
for a short time. Remedial action is to
immediately run the heater at maximum
output and to ensure adequate room
ventilation.
6. If the burner makes an unusual noise or if
the flame lifts off, it is likely that the
regulator is faulty and it is essential to
have it checked.
Technical Data
Water contents: 10/14 litres
Water pressure: up to max. 2.8 bar
Type of gas: Liquid Gas
(propane or butane)
Operating Pressure: 30mbar (or 28mbar
butane, 37mbar
propane)
Rated thermal output: 1500W
Gas consumption: 120g/h
Heating time to approx. 70°C:
Gas operation: approx. 35 mins
Electrical operation: approx. 70 mins
Gas and electrical
operation: approx. 20 mins
Power consumption 12V
Ignition: 0.17A
Heating Up: 0.08A
Standby: 0.04A
Power consumption 230V
Heating Up: (2A) 450W
Weight (empty): 6.7Kg
REFRIGERATORS
Before using your refrigerator for the first
time, it is advisable to wash the interior and
its accessories.
When using the refrigerator on gas ensure
that the gas isolation tap is fully open by
turning the knob to the vertical position. The
tap is located inside the sink unit at floor
height. When travelling the fridge can only be
operated in the 12V mode.
Note:
Before operating the refrigerator on 12V,
it should be pre-cooled, together with its
contents, by running it on gas or 230V for
a few hours before changing over to 12V
for your journey.
The current drain is approximately 7A to 14A
(model specific) and power is only available
when the ignition circuit is switched on. On
site, only the mains electric or gas modes
should be used.
The refrigerator can run on either 230V, 12V
or LP gas. Changing between these modes
of operation is carried out by means of the
controls on the control panel.
Caution: Only use one source of energy
at a time.
After initial installation, servicing or changing
gas cylinders etc., the gas lines may contain
some air which should be allowed to escape
by briefly turning on the refrigerator or other
appliances. This will ensure that the flame
lights immediately.
The flame failure device will automatically
shut off the gas to the burner if the flame is
blown out. On electric ignition versions, the
flame failure device will also shut off the gas
if the burner does not re-light within about a
minute of the flame being blown out.