10. AC Generator / Starting Clutch
10-2
Precautions in Operation
Refer to chapter 5: Engine removal and installation
Refer to chapter 16: The troubleshooting and inspection of alternator
Refer to chapter 16: The service procedures and precaution items of starter motor
Specification
Item
Standard value (mm)
Limit (mm)
ID of starting clutch gear
20.026~20.045
20.100
OD of starting clutch gear
42.175~42.200
42.100
Torque value
Flywheel nut 8.5~10.5 kgf-m
Starting clutch hexagon bolt 1.0~1.4 kgf-m with adhesive
8 mm bolts 0.8~1.2 kgf-m
12 mm bolts 1.0~1.4 kgf-m
Tools
Special tools
A.C.G. flywheel puller
Universal holder
To this chapter contents