10. Cooling System
Coolant change
10-5
Warning
Never attempt to carry out service work on the
cooling system unless the engine is
completely cooled down, otherwise, you may
get scalded.
Remove right-front body cover. (screwX2)
Remove radiator tank cap.
Remove under spoiler. (boltX4)
Place a water pan under the water pump;
loosen the drain bolt to drain out the coolant.
Reinstall the drain bolt.
Refill system with coolant and bleed the air
bubbles.
Remove radiator tank cap.
Start the engine and confirm no bubbles from
the radiator and the coolant level is stable.
Shut down engine, refill coolant if necessary.
Caution
To avoid the water tank rusting, please do
not use an unknown trademark refrigerant.
Coolant recommended: SYM Bramax radiator
agent.
Concentration: 50%
Reserve tank check
Remove left-front body cover.
Check reserve tank coolant level, refill coolant to
standard level. (between upper and lower)
Install reserve tank cap.
Caution
Do not fill too much coolant, or the collant
will backflow after the water temperature
rises.
drain bolt
Radiator tank cap
Reserve tank cap