10. Cooling System
10-6
Radiator
Removal / Check
Remove radiator air duct. (boltX3)
Check for any leakage from weld seam.
Blow radiator with compressed air. If the
radiator is blocked by dirt, use low pressure
water jet to clean it.
Care shall be taken when straightening the
sink fan.
Place a water pan under the water pump;
loosen the drain bolt to drain out the coolant.
Install drain bolt.
Remove radiator bolt. (bolt×2)
Drain bolt
bolt×2
bolt×3