MenuLevel1MenuLevel2MenuLevel3Explanation
Functions
RHtransferCtrl
RHTransferCtrl
Setpoint:OFF
P-band:20%
I-time:OFF
Usethisdialogframeto
congureintensityofextract
airhumiditycontrolwhich
helpstoavoidmoisture
transfertosupplyair.
RHtransfercontrolisenabled
ifsetpointishigherthan0.
DefaultsetpointvalueisOff.
Note:
Thesesettingsareonly
presentifheatexchanger
controllertypeissetto
Variable.
Functions
Defrosting
Defrosting
Mode0–5
Usethisdialogueframetoset
howaggressiveyouwantthe
defrostingfunctiontooperate
(seechapter7.6).
Note:
Thesesettingsareonly
presentifheatexchanger
controllertypeissetto
On/Off.
Functions
Calibration
Calibration
Sensorvalue:0%
Adjustedvalue:0%
Confirm:YES/NO
Usethisdialogueframe
tocalibrateinternalRH
sensorforanydeviationsif
necessary.
Showscurrentinputsignal
valueofRHsensor.
SetadjustedvalueforRH
sensor.
Adjustedvaluemustbe
conrmed.
SetYEStoconrmchanges.
Functions
Modbus
Modbus
Settings
Settings
Address1
Baud19200
ParityNone
InformationaboutModbus
communicationandvariables
canbefoundintheModbus
usermanualforresidential
unitsintheonlinecatalogue
at
www.systemair.com.
Modbus
Gateway
Gateway
StateNot
present/...
Showscurrentstatusof
communication.
SAVEVTR200/BInstallationandService
208061
32
SystemairSverigeAB