EasyManuals Logo

tae TA-U65 User Manual

Default Icon
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
Appendix 1 list of Parameters State 16.11.15
Misprints and technical changes reserved Page 26
17: Motorpotentiometer
ID
Name
Value-Range
Default-Value
Unit
Access
690
Digital Motorpoti Selection
0000h ... 0007h
0000h
[bits]
RW
Selection of the basic motor potentiometer functions.
Bit
Name
Note
0
Motorpoti
Activate motor potentiometer
1
Save Motorpoti value by Power down
When mains voltage OFF
2
Start Motorpoti by Zero
When motor potentiometer ON, value is always zero
17: Motorpotentiometer
ID
Name
Value-Range
Default-Value
Unit
Access
691
Digital Motorpoti Command
0000h ... 0003h
0000h
[bits]
RW
To control the motor potentiometer.
Bit
Name
Note
0
Motorpoti UP
With active ramp
1
Motorpoti DOWN
With active ramp
17: Motorpotentiometer
ID
Name
Value-Range
Default-Value
Unit
Access
692
Digital Motorpoti Status
0000h ... 0003h
---
[bits]
R
To display the motor potentiometer status.
Bit
Name
Note
0
Motorpoti
Motor potentiometer ON
1
Motorpoti UP
With active ramp
2
Motorpoti DOWN
With active ramp
3
Save Motorpoti value by Power down
When mains voltage OFF
4
Start Motorpoti by Zero
When motor potentiometer ON, value is always zero
17: Motorpotentiometer
ID
Name
Value-Range
Default-Value
Unit
Access
693
Motorpoti Wert
0,0 ... Par.101
0,0
rpm
R
694
Motorpoti Grenze oben
0,0 ... 100,0
100,0
%
RW
695
Motorpoti Grenze unten
0,0 ... 100,0
0,0
%
RW