- 24 -
The dark squares indicate the direction
the dipswitches should be set to.
Easy Link Connection Procedures
1. Choose one of your units as the “MASTER” unit.
2. “The MASTER
Locate the bank of dipswitches to the right of the 7-seg. LED on the computer board of the T-
K3/T-K3-Pro that you select to be the “MASTERunit. Change dipswitch No. 1 to “ON”. Do not
change any dipswitch settings on the “SLAVE” units.
3. Between theMASTER” and the “SLAVE-1
Connect the “MASTER connector” of the “MASTER unit” to the “SLAVE IN connector” of the
SLAVE-1 unit.
4. Between theSLAVE-1” and the “SLAVE-2
Connect the “SLAVE OUT connector” of the “SLAVE-1 unit” to the “SLAVE IN connector” of the
SLAVE-2 unit.
5. Between theSLAVE-2” and the “SLAVE-3
Connect the “SLAVE OUT connector” of the “SLAVE-2 unit to the “SLAVE IN connector” of the
SLAVE-3 unit.
6. Make sure the “Easy Link system ON LINE” lamps of all units are lit. The numbering system
of the T-K3/T-K3-Pro automatically allocates the unit # to each water heater that is part of the
Easy Link system.
Master unit Unit # : 1
Slave units Unit# : 2, 3 and 4
CAUTION
Unless you change dipswitch No.1 of the “MASTER” unit to “ON”, the system will not
work as an Easy Link system. The “Easy Link system ON LINE” lamps will stay unlit and
the units will work as individual units.
MASTE
R
unit SLAVE-1 unit
SLAVE-2 unit
SLAVE-3 unit
M
A
S
T
E
R
S
L
A
V
E
O
U
T
M
S
T
OFF
ON
D
I
R
E
O
U
T
T
M
P
3
T
M
P
2
T
M
P
1
1
2
3
4
5
6
Communication cable
S
L
A
V
E
I
N
Connectors
Dipswitch
M
A
S
T
E
R
S
L
A
V
E
O
U
T
M
S
T
OFF
ON
D
I
R
E
O
U
T
T
M
P
3
T
M
P
2
T
M
P
1
1
2
3
4
5
6
S
L
A
V
E
I
N
Connectors
Dipswitch
M
A
S
T
E
R
S
L
A
V
E
O
U
T
M
S
T
OFF
ON
D
I
R
E
O
U
T
T
M
P
3
T
M
P
2
T
M
P
1
1
2
3
4
5
6
S
L
A
V
E
I
N
Connectors
Dipswitch
M
A
S
T
E
R
S
L
A
V
E
O
U
T
M
S
T
OFF
ON
D
I
R
E
O
U
T
T
M
P
3
T
M
P
2
T
M
P
1
1
2
3
4
5
6
S
L
A
V
E
I
N
Connectors
Dipswitch
Wrong dipswitch setting on
the “MASTER” unit
MASTE
R
unit SLAVE-1 unit
M
A
S
T
E
R
S
L
A
V
E
O
U
T
M
S
T
OFF
ON
D
I
R
E
O
U
T
T
M
P
3
T
M
P
2
T
M
P
1
1
2
3
4
5
6
Communication cable
S
L
A
V
E
I
N
Connectors
Dipswitch
M
A
S
T
E
R
S
L
A
V
E
O
U
T
M
S
T
OFF
ON
D
I
R
E
O
U
T
T
M
P
3
T
M
P
2
T
M
P
1
1
2
3
4
5
6
S
L
A
V
E
I
N
Connectors
Dipswitch

Other manuals for Takagi T-K3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Takagi T-K3 and is the answer not in the manual?

Takagi T-K3 Specifications

General IconGeneral
TypeTankless
Installation TypeIndoor
Maximum BTU Input199, 000 BTU/h
Gas Connection Size3/4"
Vent Size3"
Hot Water Flow Rate (at 35°C rise)6.6 GPM
Maximum Input199, 000 BTU/h

Related product manuals