- 26 -
•  If the TM-RE30 or the TM-RE10 remote controller (optional) has to be connected to the 
“MASTER” unit. If the TM-RE30 or the TM-RE10 is connected to a “SLAVE” unit,
 it will only 
control that particular individual “SLAVE” unit and will not control the Easy Link system as a 
whole. 
 
 
 
 
 
 
 
 
PUMP CONNECTION 
The T-K3/T-K3-Pro can be used to control a recirculation 
pump. Proper pump control helps to preserve the life of the 
system and saves energy as well: The T-K3/T-K3-Pro pump 
control port is a “normally open" dry contact, and therefore 
needs additional components to properly control a 
recirculation pump. To control a recirculation pump, connect 
the pump to the “Pump” connector in the T-K3/T-K3-Pro as 
shown in the diagram to the right. (In an Easy Link system, 
connect the pump ONLY to the “MASTER” unit.) The pump 
is to be connected using suitable relays shown in the 
diagram below. Please make sure the relays are properly 
rated for the recirculation pump.  
 
Using the T-K3/T-K3-Pro’s internal thermistors as a temperature 
control, the recirculation pump will only turn on when recirculation 
is needed. 
 
 
 
•  The TM-RE30 or TM-RE10 (optional remote controller) is not required for 
the Easy Link system. 
•  If running the Easy Link system without the TM-RE30 or the TM-RE10, 
please make sure the dipswitch settings for the temperature, outdoor, and 
direct vent settings on ALL the units are set to the same settings.  
Otherwise, the units may not operate properly.  
•  If the TM-RE30 or the TM-RE10 is used, the temperature on all the units in 
the system will automatically be set to the same temperature that is set on 
the remote.  However, even with the remote, the outdoor and direct vent 
dipswitch settings still need to be set to the same settings on all the units.  
 
MASTE
unit
SLAVE unit
 
M
A
S
T
E
R
S
L
A
V
E
 
O
U
T
M
S
T
OFF
ON
D
I
R
E
O
U
T
T
M
P
3
T
M
P
2
T
M
P
1
1
2
3
4
5
6
Communication cable
S
L
A
V
E
 
I
N
Connectors
Dipswitch
M
A
S
T
E
R
S
L
A
V
E
 
O
U
T
M
S
T
OFF
ON
D
I
R
E
O
U
T
T
M
P
3
T
M
P
2
T
M
P
1
1
2
3
4
5
6
S
L
A
V
E
 
I
N
Connectors
Dipswitch
Remote 
Controller
These components are not included 
with Takagi water heaters and are 
external to the unit.  They must be 
acquired separately. 
Connect to this “Pump” connector. 
Wrong connection 
between the 
“SLAVE” 
unit and the TM-RE30 
(or TM-RE10) 
CAUTION 
In an Easy Link system, the pump must be connected 
to the “Pump” connector in the “MASTER” unit only. 
If the pump is connected to any of the “SLAVE” units, 
the pump will not work.