- 28 -
(unit:°F)
Temperatures available under the High Temperature Mode
NORMAL OPERATION
• Flow rate to activate the T-K3/T-K3-Pro : 0.5 gallon per minute
• Flow rate to keep the T-K3/T-K3-Pro running : 0.4 gallon per minute
1. NORMAL OPERATION
WITHOUT REMOTE CONTROLLER
1. Open a hot water tap.
2. Mix cold water with the hot to get
the correct temperature water.
3. Close the hot water tap.
2. NORMAL OPERATION
WITH REMOTE CONTROLLER INSTALLED: TM-RE30 (Optional)
1. Press the power ON/OFF button. 2. Set temperature. (Example 110°F)
WARNING
Hot Water temperatures over 125°F can cause severe burns
instantly or death from scalding.
• The outlet hot water temperature of the FLASH T-K3/T-K3-Pro
water heater is factory set at 122°F.
• Feel the water temperature before bathing or showering.
99 100 102 104 106 108 110 111 113 115 117 122 131 140 158 167
99 100 102 104 106 108 110 111 113 122 131 140 149 158 167 176/185
The temperature and the
time will be displayed on
the remote controller.
Temperatures available under the Default Mode
3. Open a hot water tap.
Mix cold water with the hot if you need.
4. Close the hot water tap.
When ON,
green LED is lit.
• DO NOT set to 185 °F if you use your T-K3/T-K3-Pro in recirculation system. Refer to p.30
• Refer to the TM-RE30 Installation Manual to change the setting to the High Temperature mode.
*If the TM-RE10 is used, refer to the TM-RE10 Installation Manual included with the remote.
Lamp is ON
Lamp is ON
Lamp is OFF
Lamp is OFF