- 33 -
~ WATER HEATER ~
PROBLEM POSSIBLE SOLUTIONS
Unit does not ignite when water goes
through the unit.
Is the flow rate over 0.5 GPM? (p. 28)
Check for the filter on cold water inlet. (p. 31)
Check for reverse connection and cross connection.
If you use the remote controller, is the power button
turned on? (p. 28)
The fan motor is still spinning after
operation has stopped.
This is normal. After operation has stopped, the fan
motor keeps running from 5 to 50 seconds in order
to re-ignite quickly, as well as purge all the exhaust
gas out of the flue.
Abnormal sounds come from the unit.
Contact TAKAGI.
~ REMOTE CONTROLLER: TM-RE30 (OPTIONAL) ~
PROBLEM POSSIBLE SOLUTIONS
Remote controller does not display
anything when the power button is
turned on.
Press the ON/OFF button.
If the lamp lights up
This is normal. When the unit has not operated for
five minutes or more, the display turns off to
converse energy.
If the lamp does not light
Make sure the unit has power supply.
Make sure the connection to the unit is correct.(p. 22)
An ERROR code is displayed.
Please see p. 34.
~ EASY LINK SYSTEM ~
PROBLEM POSSIBLE SOLUTIONS
How are the unit numbers assigned?
For an Easy Link system, other than the Master Unit
(which is always labeled #1), all the other units (the
Slave units) are numbered randomly.
To check which numbers are assigned to which
Slave units, push the button on the computer board
of a unit as shown below. The unit number will be
displayed on the 7-Seg LED.
Button to check
unit numbers
7-Seg LED

Other manuals for Takagi T-K3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Takagi T-K3 and is the answer not in the manual?

Takagi T-K3 Specifications

General IconGeneral
TypeTankless
Installation TypeIndoor
Maximum BTU Input199, 000 BTU/h
Gas Connection Size3/4"
Vent Size3"
Hot Water Flow Rate (at 35°C rise)6.6 GPM
Maximum Input199, 000 BTU/h

Related product manuals