1-29
SAFETY
PRECAUTIONS ON MAINTENANCE
Be careful with the high-pressure grease
In the track adjuster, the grease has been
injected under high pressure. If the tension is
adjusted without following the prescribed
procedure, the grease discharge valve may
fly off, resulting in injury.
• Never loosen the grease fitting.
• Loosen the grease discharge valve slowly.
Do not turn it more than one turns.
• Do not put your face, arms, legs or body in
front of the grease discharge valve.
• If grease does not come out when the
grease discharge valve is loosened, the
valve is faulty. Ask a Takeuchi service agent
for repair.
AG7A086
Handling of the accumulator
Be sure to handle the high-pressure nitrogen
gas enclosed in the accumulator with care. If
handled incorrectly, it could explode and
cause serious injury. Strictly observe the
following precautions:
• Do not disassemble.
• Do not allow flame near or throw it into a
fire.
• Do not drill, weld or fuse.
• Do not subject it to physical shock such as
hitting, rolling or dropping.
• Before disposing of the unit, the sealed gas
must be drained. Contact a Takeuchi
service agent for help.

Table of Contents

Other manuals for Takeuchi TB210R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Takeuchi TB210R and is the answer not in the manual?

Takeuchi TB210R Specifications

General IconGeneral
BrandTakeuchi
ModelTB210R
CategoryExcavators
LanguageEnglish

Related product manuals