CONTROLS
Switches
Detent Mode Switch
(D)
This switch changes the function
of
auxiliary
hydraulic button
(A)
. Normally auxiliary
hydraulic flow is on while button
(A)
is pressed
and turns off when it is released. If pressed
again after pressing this button, then auxiliary
hydraulic button
(A)
turns on and stays on
when it
is
pressed, and only turns off when it
is
pressed again. The built-
in
lamp (orange)
lights when the switch
is
on. Thus there
is
no
need to hold the switch
in.
When this switch
is
pressed again, the function
of
the auxiliary
hydraulic switch returns to normal and the
lamp turns off.
IMPORTANT: Do not operate the machine
in
the detent mode for a long time.
Doing
so
will increase the hydraulic
oil
temperature and shorten the service life
of the hydraulic units.
59
High-Flow Switch
(E)
- (If equipped)
This switch controls the
ON
I OFF function
of
the high-flow auxiliary hydraulics.
Press this switch to activate the high-flow
hydraulics and the hydraulic flow switches
from two-way to one-way and the built-
in
lamp and flow selector switch lamp
(green)
come on. Press this switch again to
deactivate the high-flow hydraulics and the
hydraulic flow switches from one-way back
to two-way and the lamps go out.
Refer to page
66,
"High-Flow Hydraulic
System."
O
........
.
OFF
l
........
..
ON