The following table shows how the “Turn on temperature” is obtained.
Critical Plant Temperature
Dew Point Range
Turn On Temperature
0
-16 to -12
8.2
-12 to -9
7.1
-9 to -6
6.0
-6 to -4
4.9
-4 to -2
3.8
-2 to -1
2.7
-1 to 0
1.6
-1
-18 to -13
6.6
-13 to -9
5.4
-9 to -7
4.3
-7 to -4
3.2
-4 to -3
2.1
-3 to -1
1.0
-2
-18 to -13
4.9
-13 to -10
3.8
-10 to -7
2.7
-7 to -5
1.6
-5 to -3
0.4
-3 to -2
-0.7
-3
-18 to -12
2.7
-12 to -9
1.6
-9 to -7
-0.4
-7 to -5
-0.7
-5 to -4
-1.7
Notice that:
Prior to using the Frost protection option it must be enabled at the DEALERS
DEFINITIONS.
When the calculated Dew point is out of the range of the table the displayed
turn on temperature will be 0.0.