- 47 -
For the sake of flexibility, the Radiation sets enable dividing the 24 hours of the day
into three parts and each part may have its own definition of threshold and
minimal/maximal intervals.
The selection of the Radiation sensor to be referred to is done through an
auxiliary screen containing all the analog sensors and the user has to mark
the sensor to be used. The purpose of defining the sensor’s coefficient is to
enable using the same sensor in different sets, but being able to refer to it
differently. The coefficient is expressed in %. When the coefficient equals 0
the radiation set is disabled.
Notice that:
The same Radiation set can be used by several irrigation programs.
10. Filtration
The filtration program is defined per each filtration site independently. Each program
contains the Interval between the flushing cycles, the flushing time per station,
the Dwell time between the stations and in case there exists a Down Stream
(pressure sustaining) valve, the Pre Dwell time between the opening of the Down-
Stream valve and the first station.