- 48 -
The system supplies information about the status of the Filter site, the status of the
DP sensor and the time left to the next cycle. During operation the system shows the
station which is currently being flushed, and the time left for flushing of that station.
Additional information shows the number of flushing cycles executed by time, by DP
and the number of consecutive loops executed.
Notice that:
When there is no irrigation in progress, the countdown of the interval to next
flushing is halted.
By default, backflushing will start always with the first filter station on site.
However there is an option to request (through the DEALERS
DEFINITIONS) that the flushing will start with the filter following the one
that was the last to be flushed at the end of the previous cycle.
During the DEALERS DEFINITIONS, it can be decided whether or not to
ignore the DP sensor during the line filling delay.
Execution of any flushing cycle, no matter what caused it to start, will reset
the left interval to its programmed value.
The constants of the filter site define what will happen with the irrigation
during the flushing process.