Operation
The basic commands needed for programming the Modem are provided in
Table
3.
Table
4
lists the dialing and answering commands. For
a
detailed
explanation of each command, refer to Appendix
A,
Command reference.
Commands with parameters
Some of the commands have parameters. The parameter value, usually
0,
1
or
2,
follows the command. When the command parameter is not used,
the Modem assumes
a
value of
0.
For example, the echo command
E
does
not echo when parameter
0
is assumed. It does echo when parameter
1
is
issued.
E
used alone is the same
as
EO.
Table
2.
Commands
with
Parameters
~ ~~~
~~
Code
Parameter Function Default
Q
0
1
V
0
1
E
0
1
F
0
1
M
0
1
2
C
0
1
H
0
1
Result codes ON.
Result codes OFF.
Numeric result codes.
Verbal result codes.
Commands are not
echoed.
Echo commands.
Half duplex.
Full duplex.
Monitor speaker always
OFF.
Monitor speaker ON
until carrier-detect.
Monitor speaker always
ON.
Transmitter OFF.
Transmitter
ON.
ON
HOOK (phone line is
Defined by DIP Switch
4.
Defined by DIP Switch
3.
Defined by DIP Switch
5.
F1
M1
c1
disconnected when not in
use). HO
OFF
HOOK
(phone line is
connected regardless of
its condition).
18