START
ES_EN_
READY!
T= +2º C W -14
Cylinder +12º C
Hopper +14º C
Set=100 Hot=051
HOT Autotuning
Cones Today
00375
Total Cones
0473161942
TEV+010
TCN+039
TEC+013
TGV-022
TRC+017
TE1-012
MAIN SCREEN:
• Soft-cream state
•
• Días que faltan para el siguiente lavado
TEMPERATURE:
• Bowl Temperature.
• Cylinder Temperature.
CONSISTENCY:
• HOT: Current consistency value.
• SET: Consistency value to be reached.
TEMPERATURE SENSORS:
• TCN: Condenser
• TRC: Compresor
DAILY CONES:
• We can see how many cones we have served
today. (From 0:00 to 23:59)
TOTAL CONES:
• We can see the total amount of cones served
by the machine.
Bowl
Evaporator
Bowl
Evaporator Exit
Cylinder
Evaporator
Cylinder
Evaporator Exit
TEMPERATURE SENSORS:
• TEV: • TGV:
• TEC: • TE1:
A downward arrow indica-
tes that the cylinder is coo-
ling down.
0
1
2
3
4
5
6
Prepare soft-creamStart-up
Push START
When the Soft-Cream is ready, the screen will show:
READY!
Push main Switch.
Machine charged.
1 2
DURING PREPARATION WE CAN SEE:
(Pushing we can change the information screen)
4.3 Soft-Cream Production
4.Operation
13