19
Models 104 & 220
Troubleshooting
Model 104 (Cont’d.)
PROBLEM PROBABLE CAUSE REMEDY
6. The product is not freezing. a. The timer control is not set or
is defective.
a. Set time for required batch or
replace the timer.
b. The condensers are dirty on
air cooled units.
b. Clean condensers monthly.
c. The control switch is not in the
AUTO position.
c. Put t he control switch into the
AUTO position for compressor
operation.
7. There is excessive mix
leakage in the rear drip tray.
a. The seal on the beater drive
shaft is missing or worn.
a. Install or replace the seal on
the beater drive shaft.
b. The rear shell bearing is worn. b. Replace the bearing.
c. There is improper lubrication
on the beater drive shaft.
c. Lubricate properly.
8. The buzzer does not sound
when the unit cycles off.
a. The buzzer is malfunctioning. a. Replace the buzzer .