17
Models 60 & 62 Operating Procedures
Locate the spinner coupling and slip it over the slotted
end of the spinner blade shaft. Raise the slip collar on
the coupling and turn the shaft from the bottom until the
spinner coupling slips down into its locking position.
Figure 21
Rotate the draw valve to the left, and center it in
position on the draw arm. Place the draw arm into the
slotted groove of the draw valve bracket.
Figure 22
Step 9
Install the torque arm. Position the torque arm by first
slipping it up through the slot in the operating arm.
Secondly, align the other end down in the hole in the
torque rotor shaft which protrudes from the door.
Figure 23
Check the torque arm by moving it back and forth to be
sure it moves freely and easily.
Figure 24
Step 10
Connect the syrup lines. Connect the syrup lines of the
spinner housing to the quick disconnect fittings on the
front panel.