18
Models 60 & 62Operating Procedures
080701
Step 11
Install the front drip tray and the splash shield.
Figure 26
Sanitizing
Step 1
Prepare an approved 100 PPM sanitizing solution
(examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R or 2
gal. [7.6 liters] of Stera- SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS.
NOTE: BEFORE HANDLING SANITIZED
PARTS, SANITIZE YOUR HANDS!
Step 2
Lay the feed tube in the bottom of the mix hopper.
Figure 27
Step 3
Pour the sanitizing solution into the mix hopper and
allow it to flow into the freezing cylinder.
Figure 28
While the sanitizing solution is bubbling down into the
freezing cylinder, brush clean the mix hopper. While
cleaning the mix hopper, be sure to brush the mix level
sensing probe on the rear wall of the hopper.
Figure 29
Brush clean the mix inlet hole and the feed tube.