EasyManua.ls Logo

Taylor 8756 - Cleaning

Taylor 8756
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATING PROCEDURES
6-15
Model 8756
Operating Procedures
6
Figure 6-59
8. Disconnect the pressure line from the pressure
switch. Drain the water and then reconnect.
9. Repeat this procedure using clean, warm water until
the water being discharged is clear.
10. Repeat these steps for the second freezing
cylinder.
Cleaning
1. Prepare a pail of approved 100 ppm cleaning solution
(examples: 2-1/2 gal. [9.5 L] of Kay-5
®
or
2 gal. [7.6 L] of Stera-Sheen
®
). Use warm water and
follow the manufacturer's specifications.
2. Place the pail of cleaning solution inside the mix
cabinet and insert the suction line.
Figure 6-60
3. Disconnect the pressure line from the pressure
switch and place it in the pail of cleaning solution.
4. Press the PUMP key. This action will cause the
cleaning solution to be pumped through the air/mix
pump and out through the pressure line. After
approximately 15 seconds, press the PUMP key to
stop operation.
Figure 6-61
5. Drain and connect the free end of the pressure line to
the pressure switch.
6. Place an empty pail beneath the door spout. Raise
the prime plug and press the WASH and PUMP keys.
.
Figure 6-62
7. When a steady stream of solution is flowing from the
prime plug hole in the bottom of the freezer door,
open the draw valve and draw off the remaining
cleaning solution.
13038wp
15067
13038p
13038wp

Related product manuals