OPERATING PROCEDURES
6-5
085592-M
Operating Procedures
6
20. Install the drip pan.
Figure 6-16
Sanitizing
1. Prepare an approved 100 PPM sanitizing solution
(examples: 2.5 gal. [9.5 L] of Kay-5
®
or 2 gal. [7.6 L]
of Stera-Sheen
®
). Use warm water and follow the
manufacturer's specifications.
2. Pour 1 gal. (3.8 L) of sanitizing solution into the
hopper and allow it to flow into the freezing cylinder.
Figure 6-17
3. While the solution is flowing into the freezing cylinder,
brush clean the mix hopper, the mix inlet hole, and
the feed tube.
Figure 6-18
Figure 6-19
4. Place the power switch in the ON position.
Figure 6-20
12029
12235
12019
13093
131559