17
Model C300 Important: To the Operator
Syrup Out Indicator
AUTO MODE AUTO
OUT SYRUP OK
CO2--OK WATER--OK
If the word “OUT” appears in one of the columns
next to the word “SYRUP”, it indicates a lack of
syrup or syrup pressure being supplied for the
indicated freezing cylinder . If the unit is in the AUTO
or PRIME modes, the product light will illuminate
and a warning tone will sound for that freezing
cylinder. At this time, replace the appropriate
bag--in--the--box. As a safety feature, the
refrigeration system automatically stops to prevent a
freeze--up in the freezing cylinder.
If a syrup out condition occurs on one side, that side
will enter the HOLD mode at which time refrigeration
remains off, the beater continues to run, and the
CO
2
solenoid is closed for that side to prevent the
dispensing of product. The opposite side will not be
affected.
CO
2
Out Indicator
AUTO MODE AUTO
OK SYRUP OK
CO2--OUT WATER--OK
On the LCD, if the word “OUT” appears next to the
word “CO2 it indicates a lack of CO2 being supplied
to the freezer. The product light will also illuminate
and a warning tone will sound. This will continue
until the CO2 is replaced. If the CO2 is not replaced
within one minute, the machine will shut down and a
fault message will appear.
Water Out Indicator
AUTO MODE AUTO
OK SYRUP OK
CO2--OK WATER--OUT
On the LCD, if the word “OUT” appears next to the
word “WATER”, it indicates a lack of water being
supplied to the freezer . In addition, the product light
will illuminate and a warning tone will sound. This
will continue until the proper amount of water is
supplied to the freezer . If the water is not supplied
within one minute, the machine will shut down and a
fault message will appear.
Audio Alarm Silencer
The audio alarm will be disabled if the ALARM
SILENCE key is pressed. If a new fault or fault
condition occurs or the system mode changes, the
audio alarm will be re--enabled automatically. If the
audio alarm is silenced for greater than 30 minutes
without correcting the fault, it will be re--enabled
automatically.
Product Light
When the light is continuously lit (not flashing) it
indicates that there is an “OUT condition for syrup,
water, or CO
2
.
When the light is flashing, it indicates that the
product is not at serving viscosity. This will occur
during the initial freeze down, a defrost cycle and a
F AULT condition and during power saver modes.
Sampling Valve
The sampling valve is located behind the lower front
panel. The sampling valve is used to obtain a brix
reading.
Daily Procedures
The following procedure should be performed daily.
Remove the splash shield and front drip tray. Take
these parts to the sink and brush--clean them.
Re--install the parts onto the freezer. Use a clean,
sanitized towel and wipe down the front of the
machine, including the doors and spouts.

Other manuals for Taylor C300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor C300 and is the answer not in the manual?

Taylor C300 Specifications

General IconGeneral
BrandTaylor
ModelC300
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals