AIR COOLED
CONDENSER FAN
M
BLK
WATER COOLED
BLK
*IF THE UNIT HAS THE INTEGRAL SYRUP OPTION -405, THEN THIS JUMPER SHOULD BE INSTALLED.
JUMPER SETTINGS
1
2
3
4
T8
T1
T7
T4
T5
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
LEESON BEATER MOTOR WIRING
STEPS:
1) DISCONNECT WIRE T7 FROM TERMINAL 3
2) SPLICE BLUE WIRE AS SHOWN
1
2
4
6
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
A.O. SMITH BEATER MOTOR WIRING
STEPS:
1) REMOVE BROWN JUMPER FROM BETWEEN TERMINAL #1 TO TERMINAL #5
2) MOVE BLUE INTERNAL (FROM MOTOR MAIN WINDING)
FROM TERMINAL #5 TO TERMINAL #1.
NOTE: FOR CCWLE - BLUE INTERNAL ON #1, YELLOW INTERNAL ON #6
BLUE INTERNAL
3
5
ORANGE INTERNAL
RED INTERNAL
YELLOW INTERNAL
BLACK INTERNAL
BLUE
BLUE
T3 L3
USE T3 AND L3 WHEN
CP CONTACTS ARE NOT AVAILABLE
T3 L3
USE T3 AND L3 WHEN
CP CONTACTS ARE NOT AVAILABLE
RED
WHT
M
BLU/WHT
BLUE
AGITATOR MOTOR
DETAIL
SE
BLUE
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
GE/RBC/MARATHON BEATER MOTOR WIRING
NOTE: FOR CCWLE - BLUE INTERNAL ON #1,YELLOW INTERNAL ON #2
BLUE
T3 L3
USE T3 AND L3 WHEN CP
CONTACTS ARE NOT AVAILABLE
J12 OR PURPLE INTERNAL
T1 OR BLUE INTERNAL
T8 OR RED INTERNAL
J9 OR BLACK INTERNAL
A
1
4
5
T4 OR YELLOW INTERNAL
2
FIG. 1
(SEE FIG. 1)
(SEE FIG. 1)
BLK
BLK/BLU
BLK
C
L
C
L
UVC4 BOARD FUNCTION
JUMPER
INSTALLED
INITIALLY
JP1
PINS 1 AND 2
JUMPER INSTALLED - BARREL AND HOPPER
TEMPERATURES ARE CHECKED DURING
AUTO/STANDBY. UNIT IS LOCKED OUT IF
EITHER BARREL OR HOPPER IS TOO WARM FOR
A PERIOD OF TIME. LOCKOUT OCCURS WHEN
BARREL OR HOPPER IS ABOVE 45F(7C) FOR
MORE THAN ONE HOUR OR ABOVE 41F(5C) FOR
MORE THAN FOUR HOURS.
YES
NO JUMPER INSTALLED - NO LOCKOUT DURING
AUTO/STANDBY IF BARREL OR HOPPER IS TOO
WARM FOR A PERIOD OF TIME.
PINS 3 AND 4
RESERVED (DO NOT USE)
NO
JP2
PINS 1 AND 2
DOMESTIC CONFIGURATION - JUMPER
INSTALLED. HOPPER TEMPERATURE NOT
DISPLAYED ON SCREEN/HEAT SYMBOL KEYS
ONLY ACTIVE WHEN A LOCKOUT CONDITION
HAS OCCURRED/STANDBY KEYS DISABLED.
YES
INTERNATIONAL CONFIGURATION - NO JUMPER
INSTALLED. HOPPER TEMPERATURES
DISPLAYED ON SCREEN/MANUAL HEAT CYCLE
START BY SELECTING HEAT SYMBOL/STANDBY
KEYS FUNCTIONAL.
JP3
RESERVED (DO NOT USE)
.
NO
JP4
RESERVED (DO NOT USE)
.
NO
JP5
RESERVED (DO NOT USE)
.
NO
JP6
RESERVED (DO NOT USE)
.
NO
JP7
JUMPER INSTALLED DISABLES RESET.
.
NO
RTCK
RESERVED (DO NOT USE)
.
NO
DBGEN
RESERVED (DO NOT USE)
.
NO
LEFT
INTERFACE
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
W1 NO
W2
JUMPER INSTALLED - FORCE BRUSH CLEAN
STATUS.
NO
W3
JUMPER INSTALLED - ACTIVATES SYRUP
HEATERS
NO*
W4
JUMPER INSTALLED - OPEN ALL LEFT
SOLENOIDS.
NO
W5 RESERVED (DO NOT USE) NO
W6
JUMPER INSTALLED - REDUCED MIX LOW
SENSITIVITY.
NO
W7
JUMPER INSTALLED - REDUCED MIX OUT
SENSITIVITY.
NO
J10 PINS 7 & 8
JUMPER INSTALLED W/SWITCH - SELF SERVE
APPLICATION ONLY. LOCKS OUT TOUCH
PANEL. NEW SWITCH ACTS AS THE ON/OFF
ABILITY TO ACTIVATE THE TOUCH PANEL.
NO
A
SOFT SERVE
PERSONALITY BOARD
0-6 AMP BEATER MOTOR AMPERAGE RANGE NO
B
SOFT SERVE
PERSONALITY BOARD
0-12 AMP BEATER MOTOR AMPERAGE RANGE YES
RIGHT
INTERFACE
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
W1 RESERVED (DO NOT USE) NO
W2
JUMPER INSTALLED - ENABLES 59F HOPPER
TEMPERATURE CHECK.
YES
W3 RESERVED (DO NOT USE) NO
W4
JUMPER INSTALLED - OPEN ALL RIGHT
SOLENOIDS.
NO
W5 RESERVED (DO NOT USE) NO
W6
JUMPER INSTALLED - REDUCED MIX LOW
SENSITIVITY.
NO
W7
JUMPER INSTALLED - REDUCED MIX OUT
SENSITIVITY.
NO
A
SOFT SERVE
PERSONALITY BOARD
0-6 AMP BEATER MOTOR AMPERAGE RANGE NO
B
SOFT SERVE
PERSONALITY BOARD
0-12 AMP BEATER MOTOR AMPERAGE RANGE YES
A
B
A
B
J13
J1
J13
J1
ADDITIONAL DRAW SWITCH
FOR FLAVORBURST
DRAW
SWITCH
C0M
PANEL
JACK
NO
NC
RED
BLK
DRAW
SWITCH
C0M
NO
NC
ADDITIONAL DRAW SWITCH
FOR FLAVORBURST
PANEL
JACK
RED
BLK
GRN/YEL
GRN/YEL
24 VAC
COM
BLU/WHT
WHT
BLU
BLUE
208
BLK/BLU
BLK/BLU
BLK/BLU
WHT
WHT/BRN
WHT/BRN
WHT
WHT
LEFT FAN
PRESSURE
SWITCH
RIGHT FAN
PRESSURE
SWITCH
BLK
BLK
BLK
WHT
WHT
SYRUP HEATER
THERMOSTA
190
F OPEN
140
F CLOSE
WHT
WHT
WHT
WHT
O.T.
FIG .4
LEFT SYRUP HEATER
OPTIONAL
SEE FIG. 4
RIGHT SYRUP HEATER
OPTIONAL
SEE FIG. 4
SELF-SERVICE
ENABLE
ENABLE
DISABLE
(OPTIONAL)
BLK
J1
1
2
GRD
+5V
CLR
J2
J7
UNIVERSAL CONTROL PCB A.
J9
J12
J17
J15
J8
5
4
6
2
1
3
J13
J4
J16
CABLE
RED
GRN
WHT
BLK
RIBBON CABLE
RIBBON CABLE
J3
EQUIPOTENTIAL
GROUND
GRN/
YEL
GRN/
YEL
BLK
COMPRESSOR
CRANKCASE HEATER
BLK
BLK
COPELAND COMPRESSORS
ONLY
COMPRESSOR
CRANKCASE HEATER
BLK
BLK
COPELAND COMPRESSORS
ONLY
BLK
BLK