NOTE:
1. STATIC ELECTRICITY MAY CAUSE
DAMAGE TO SOLID STATE COMPONENTS.
ELIMINATE STATIC ELECTRICITY BY
TOUCHING GROUNDED UNIT BEFORE
HANDLING SOLID STATE COMPONENTS.
2. RED WIRE ON RIBBON CABLES MUST BE
CONNECTED TO PIN 1 AT EACH END.
UVC4 BOARD FUNCTION
JUMPER
INSTALLED
INITIALLY
JP1
PINS 1 AND 2
JUMPER INSTALLED - BARREL AND HOPPER
TEMPERATURES ARE CHECKED DURING
AUTO/STANDBY. UNIT IS LOCKED OUT IF
EITHER BARREL OR HOPPER IS TOO WARM FOR
A PERIOD OF TIME. LOCKOUT OCCURS WHEN
BARREL OR HOPPER IS ABOVE 45F(7C) FOR
MORE THAN ONE HOUR OR ABOVE 41F(5C) FOR
MORE THAN FOUR HOURS.
YES
NO JUMPER INSTALLED - NO LOCKOUT DURING
AUTO/STANDBY IF BARREL OR HOPPER IS TOO
WARM FOR A PERIOD OF TIME.
PINS 3 AND 4
RESERVED (DO NOT USE)
NO
JP2
PINS 1 AND 2
DOMESTIC CONFIGURATION - JUMPER
INSTALLED. HOPPER TEMPERATURE NOT
DISPLAYED ON SCREEN/HEAT SYMBOL KEYS
ONLY ACTIVE WHEN A LOCKOUT CONDITION
HAS OCCURRED/STANDBY KEYS DISABLED.
NO
INTERNATIONAL CONFIGURATION - NO JUMPER
INSTALLED. HOPPER TEMPERATURES
DISPLAYED ON SCREEN/MANUAL HEAT CYCLE
START BY SELECTING HEAT SYMBOL/STANDBY
KEYS FUNCTIONAL.
JP3
RESERVED (DO NOT USE)
.
NO
JP4
RESERVED (DO NOT USE)
.
NO
JP5
RESERVED (DO NOT USE)
.
NO
JP6
RESERVED (DO NOT USE)
.
NO
JP7
JUMPER INSTALLED DISABLES RESET.
.
NO
RTCK
RESERVED (DO NOT USE)
.
NO
DBGEN
RESERVED (DO NOT USE)
NO
LEFT
INTERFACE
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
W1 NO
W2
JUMPER INSTALLED - FORCE BRUSH CLEAN
STATUS.
NO
W3
JUMPER INSTALLED - ACTIVATES SYRUP
HEATERS
NO*
W4
JUMPER INSTALLED - OPEN ALL LEFT
SOLENOIDS.
NO
W5 RESERVED (DO NOT USE) NO
W6
JUMPER INSTALLED - REDUCED MIX LOW
SENSITIVITY.
NO
W7
JUMPER INSTALLED - REDUCED MIX OUT
SENSITIVITY.
NO
J10 PINS 7 & 8
JUMPER INSTALLED W/SWITCH - SELF SERVE
APPLICATION ONLY. LOCKS OUT TOUCH
PANEL. NEW SWITCH ACTS AS THE ON/OFF
ABILITY TO ACTIVATE THE TOUCH PANEL.
NO
A
SOFT SERVE
PERSONALITY BOARD
0-6 AMP BEATER MOTOR AMPERAGE RANGE NO
B
SOFT SERVE
PERSONALITY BOARD
0-12 AMP BEATER MOTOR AMPERAGE RANGE YES
RIGHT
INTERFACE
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
W1 RESERVED (DO NOT USE) NO
W2
JUMPER INSTALLED - ENABLES 59F HOPPER
TEMPERATURE CHECK.
YES
W3 RESERVED (DO NOT USE) NO
W4
JUMPER INSTALLED - OPEN ALL RIGHT
SOLENOIDS.
NO
W5 RESERVED (DO NOT USE) NO
W6
JUMPER INSTALLED - REDUCED MIX LOW
SENSITIVITY.
NO
W7
JUMPER INSTALLED - REDUCED MIX OUT
SENSITIVITY.
NO
A
SOFT SERVE
PERSONALITY BOARD
0-6 AMP BEATER MOTOR AMPERAGE RANGE NO
B
SOFT SERVE
PERSONALITY BOARD
0-12 AMP BEATER MOTOR AMPERAGE RANGE YES
A
B
A
B
J13
J1
J13
J1